Description of Radial Guide Catheter

Single-use Radial Guide Catheter(abbreviated as guide catheter) consists of hub, protective tube, body, proximal end, remote end and distal end, among them, protective tube, body, proximal end, remote end and distal end are made from PA, PTFE and 304 stainless steel, hub is made from PC. The hydrophilic coating over the catheter is to be smooth to insert.

WARNINGS OF USAGE

·Single use only. Reuse, resterilize or reproduce may damage the completeness or function of the product. Also the product is hard to wash after using, reuse may cause the adverse reaction to patients.

·Do not use together with ethiodized oil, Lipiodol contrast solution or contrast solution contains these two material.

PRODUCTS CARACTERISTIC

Peripheral

rBwBEmR4Lb6AYuv2AABVywamtXA569.png?ct=webp

Wide lumen - a wide lumen for easy access to guidewires, balloons, stents, and more.

rBwBEmR4LcyARquQAABkUdeGljA348.png?ct=webp

PTFE coating technology - The inner PTFE coating reduces frictional resistance and makes the delivery of the device smoother.

rBwBEmR4Lc2AEVnyAABLq64plf0705.png?ct=webp

Smooth transitional four-stage design - head-end tube: soft and non-invasive, and has excellent developability;

distal tube: optimize the flexibility of the head to ensure the gentle operation and the coaxiality of blood vessels;

proximal Tube: nylon polymer material provides strong support; main tube: hard and supple, to ensure accurate twisting performance.

rBwBEmR4Lc6AX8mHAABRdYnACko714.png?ct=webp

COMPANY INTRODUCTION

As a national hi-tech enterprise, Zhejiang Barty Medical Technology Co.,Ltd is committed to the R&D, production and sales of cardio vascular, peripheral vascular and medical equipment with high technology. The products mainly includes paclitaxel eluting PTCA balloon expansion catheter, paclitaxel eluting PTA balloon expansion catheter, paclitaxel-eluting peripheral stent system, PTA balloon catheter, HP PTA balloon catheter, angiography catheter, guide catheter and catheter sheath sets.

System Certification

Barty has passed ISO 13485 quality management system certification approved by TUV-SUD in October, 2016; passed assessment of Chinese medical device registration quality management system in January, 2017; passed ISO 13485 quality management system certification approved by BS in July, 2017.

rBwBEmR4LnqAUyXnAALD-_cNmbM408.png?ct=webp